YeongHyeon / Arrhythmia_Detection_RNN_and_Lyapunov

Official source code of Arrhythmia Detection

Home Page:https://onlinelibrary.wiley.com/doi/full/10.1002/tee.22927

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

Arrhythmia Detection in ECG based on RNN Encoder–Decoder with Lyapunov Exponent

Introduction

This repository provides the source code of the paper "Arrhythmia Detection in Electrocardiogram based on Recurrent Neural Network Encoder–Decoder with Lyapunov Exponent".

The sample raw and preprocessed data. The sampling rate of raw ECG is 360 Hz. We extract 180-dimensional Lyapunov spectrum (LS) from the 360-dimensional ECG signal.

The structure of RNN Encoder-Decoder. The input of this RNN is LS and RNN reconstruct the output same as input. Above RNN cannot reconstruct unseen data well, so reconstruction error of arrhythmia ECG is lager than healthy ECG.

Comparison of the effect of using the Lyapunov exponent. Label '100' and '103' are normal (healthy) and mixed (healthy and arrhythmia). Two subfigures are shown, Euclidean distance (restoration error) of using raw ECG and Lyapunov exponent, respectively. In the right subfigure, the data that have a higher value than others contain arrhythmia.

The example of arrhythmia detection. Label '100', '103', and '107' are normal (healthy), mixed (healthy and arrhythmia), and arrhythmia respectively.

Requirements

  • Python 3.5.2
  • Tensorflow 1.4.0
  • Numpy 1.13.3
  • Scipy 1.2.0
  • Matplotlib 3.0.2

Database

You can download the original MIT-BIH Arrhythmia Database in physiobank.

BibTeX

@Article{doi:10.1002/tee.22927,
  author = {Park, YeongHyeon and Yun, Il Dong},
  title = {Arrhythmia detection in electrocardiogram based on recurrent neural network encoder–decoder with Lyapunov exponent},
  journal = {IEEJ Transactions on Electrical and Electronic Engineering},
  volume = {0},
  number = {0},
  keywords = {arrhythmia detection, recurrent neural network encoder-decoder Lyapunov exponent},
  doi = {10.1002/tee.22927},
  url = {https://onlinelibrary.wiley.com/doi/abs/10.1002/tee.22927},
  eprint = {https://onlinelibrary.wiley.com/doi/pdf/10.1002/tee.22927},
}