Giters
NordicSemiconductor
/
pc-nrfconnect-ppk
Power Profiler app for nRF Connect for Desktop
Geek Repo:
Geek Repo
Github PK Tool:
Github PK Tool
Stargazers:
101
Watchers:
22
Issues:
39
Forks:
31
NordicSemiconductor/pc-nrfconnect-ppk Issues
CSV Export: digital logic bits column headers are in reverse order
Updated
2 months ago
Is it possible to get the Voltage level in ampere meter mode ?
Updated
3 months ago
Comments count
8
Power ProfilerPower Profiler这个APP有用C++的开源动态库吗?或者可以提供一下这个APP的调用函数的相关信息?
Closed
3 months ago
Incorrect link in data loss error message
Closed
4 months ago
Dark Theme?
Closed
5 months ago
Comments count
1
Power Profiler current measurements showing 0 on 100ms scale.
Closed
7 months ago
Comments count
6
Power Profiler max current shows wrong units
Closed
7 months ago
Comments count
2
feature requests
Updated
10 months ago
Comments count
14
Time scale way off
Updated
10 months ago
Comments count
15
[Feature] Is it possible to allow sampling periods greater than 500 seconds?
Closed
a year ago
Comments count
3
COM port is busy (access denied) or generally just doesn't work
Updated
a year ago
Comments count
42
nrf conn pc升级到4.1.1后,ppk2无法检测到Jlink设备
Closed
a year ago
Comments count
1
Logarithmic scale
Closed
a year ago
Comments count
2
Save/Load does not work
Closed
a year ago
Comments count
1
Voltage measurement possible in hardware?
Closed
a year ago
Comments count
1
[feature] PPK mobile app
Closed
2 years ago
Comments count
1
PPK 2 not detected after 3.5.0 update
Closed
2 years ago
Comments count
4
Understanding adc value computation in Ampere Mode
Closed
2 years ago
Comments count
3
Incorrect Time Scaling on PPK2
Closed
2 years ago
Comments count
32
Power profiler fails on first connection to PPK
Closed
2 years ago
Comments count
10
Option in Source Meter Mode to not go over 3.3v (or be able to set any top value)
Closed
3 years ago
Comments count
6
Sampling parameters - RAM
Closed
3 years ago
Comments count
7
Cannot detect the serial ports of PPK (v3.2.0)
Closed
3 years ago
Comments count
3
logic analyzer for digital channels
Closed
3 years ago
Comments count
1
Empty export
Closed
3 years ago
Comments count
3
Chart issues when loading from saved capture file
Closed
3 years ago
Comments count
3
Set VDD feature is not working at all - PPK
Closed
3 years ago
Comments count
3
Power profiler fails to start profiling on MacOS
Closed
4 years ago
Comments count
5
Digital channels do not update
Closed
4 years ago
Comments count
3
ppk2 ampere meter measure error.not correct
Closed
4 years ago
Comments count
1
Renderer process uses a lot of CPU
Closed
4 years ago
Comments count
10
Suggestion: Do not reset Current axis (Y) when going live
Closed
4 years ago
Comments count
2
Feature request: Snap plot to whole numbers when zooming
Closed
4 years ago
Comments count
2
Feature request: Export data
Closed
4 years ago
Comments count
6
Setting VDD does not work consistently/properly
Closed
4 years ago
Comments count
8
Connecting to PPK through J-Link makes other J-Link lose target connection
Closed
5 years ago
Comments count
5
Cannot read property 'toLowerCase' of undefined
Closed
5 years ago
Comments count
2
how to Measuring current on custom hardware without nRF5 DK(SEGGER J-Link)
Closed
5 years ago
Comments count
5
[Feature Requests] Battery Life Simulation and Selection
Closed
6 years ago
Comments count
1