Erriez / R421A08-rs485-8ch-relay-board

Python 8 Channel RS485 MODBUS RTU relay board type R421A08

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

8 Channel RS485 MODBUS RTU relay board type R421A08

This Python project can control up to 64 individual 8 channel R421A08 relay boards from the command line and GUI. It uses a universal USB - RS485 dongle.

Project features:

  • Python packages for easy application integration.
  • Simple command line interface, useful for scripting.
  • wxPython GUI tested with Python 3.5 only (Windows 10 and Ubuntu 16.04)
  • Unit tests with coverage.

Hardware

The following hardware is required for this project:

  • One or more R421A08 relay boards.
  • RS485 - USB dongle.
  • Optional: A second RS485 - USB dongle to monitor MODBUS frames.

R421A08 relay board

R421A08 board

  • RS485 (binary) interface.
  • 8 x 12V Relays: 10A 125VAC / 10A 28VDC.
  • 8 status LED's.
  • 6 DIP switches for 64 board addresses.
  • Board power: 12V DC.
  • Current board idle: ~11mA.
  • Current one relay: ~26mA.
  • Current all relays on: ~220mA.
  • Length: 90mm, width: 60mm, height: 20mm.

WARNING: DO NOT USE THIS RELAY BOARD WITH 230V AC!
The distance between relay traces on the PCB are < 2mm without holes for isolation. This is dangerous when using it with high voltages. See the picture above.

R421B16 relay board

The 16 relay board version works by changing NUM_RELAYS = 16 in R421A08.py as reported by a user in issue #1.

RS485 - USB dongle

This project requires a RS485 - USB dongle which is widely available, for example:

RS485 - USB dongle

  • On Windows, open the Device Manager | Ports (COM & LPT) to find the USB-SERIAL CH340 (COMxx) serial port.
  • On Linux, use the dmesg command to find the serial port, such as /dev/ttyUSB0.

Software

Screenshot R421A08 relay GUI

Screenshot R421A08 Relay Control GUI

Screenshot MODBUS GUI

Screenshot MODBUS GUI

Screenshot commandline

Screenshot MODBUS GUI

Screenshot relay toggle example

Screenshot MODBUS GUI

Usage relay_boards Python package

getting_started.py

import time
import relay_boards


if __name__ == '__main__':
    print('Getting started R421A08 relay board\n')

    # Create MODBUS object
    _modbus = relay_modbus.Modbus(serial_port=SERIAL_PORT)

    # Open serial port
    try:
        _modbus.open()
    except relay_modbus.SerialOpenException as err:
        print(err)
        sys.exit(1)

    # Create relay board object
    board = relay_boards.R421A08(_modbus, address=1)

    print('Status all relays:')
    check(board.print_status_all())
    time.sleep(1)

    print('Turn relay 1 on')
    check(board.on(1))
    time.sleep(1)

    print('Turn relay 1 off')
    check(board.off(1))
    time.sleep(1)

    print('Toggle relay 8')
    check(board.toggle(8))
    time.sleep(1)

    print('Latch relays 6 on, all other relays off')
    check(board.latch(6))
    time.sleep(1)

    print('Turn relay 4 on for 5 seconds, all other relays off')
    check(board.delay(4, delay=5))
    time.sleep(6)

    print('Turn relays 3, 7 and 8 on')
    check(board.toggle_multi([3, 7, 8]))
    time.sleep(1)

    print('Turn all relays on')
    check(board.on_all())
    time.sleep(1)

    print('Turn all relays off')
    check(board.off_all())
    time.sleep(1)

Documentation

Please refer to the Wiki page for installation and usage.

MODBUS Application Protocol Specification v1.1.b

The following Python packages are available in this project:

  • R421A08 relay board Python package:
    • Read state relay(s).
    • Turn relay(s) on.
    • Turn relay(s) off.
    • Toggle relay(s).
    • Latch relay (One relay on, rest off).
    • Momentary (Turn relay on for one second).
    • Delay (Turn relay on for 1..255 seconds).
    • Single or multiple relay boards.
  • Serial MODBUS Python package:
    • MODBUS monitor frames on the RS485 bus
    • Send raw ASCII MODBUS frames

RS485 RTU MODBUS communication protocol

MODBUS is an open binary serial communication protocol, mainly used for PLCs.

  • Serial port at 9600 baud, 8 databits, 1 stop, no parity.
  • This board supports MODBUS RTU protocol only.
  • This board supports 64 addresses, configurable with 6 DIP switches.
  • This board does not support ASCII mode, but can be send with the Python--send option.
  • This board does not support AT commands.
  • This board does not support broadcasts.
  • All relays are off after power-on.

About

Python 8 Channel RS485 MODBUS RTU relay board type R421A08

License:MIT License


Languages