The File Format

  • 5D 00 00 00 00 00 00 00 first 8 bytes is the length of a message, this one.
  • 00 next byte denounce that this is a ProxySQL log message or not, if not 00, not valid.

The next after this line needs read_encoded_length function which itself needs mysql_decode_length function.

  • 0A this is the thread id because it is less than or equal 0xFB, convert to uint64.
  • 06 this is the length of username because it is less than or equal 0xFB, convert to uint64.
  • 64 69 64 61 73 79 is the username in ASCII.
  • 12 this is the length of schema because it is less than or equal 0xFB, convert to uint64.
  • 69 6E 66 6F 72 6D 61 74 69 6F 6E 5F 73 63 68 65 6D 61 is the schema in ASCII.
  • 0F this is the length of client address because it is less than or equal 0xFB, convert to uint64.
  • 31 32 37 2E 30 2E 30 2E 31 3A 33 32 38 32 30 is the client address in ASCII.
  • FE this tell us to read the next 8 bytes as uint64.
  • FF FF FF FF FF FF FF FF this is the HID in uint64, if HID == UINT64_MAX then we don't have server address to read.
  • FE this tell us to read the next 8 bytes as uint64.
  • 91 00 B3 4A 28 86 05 00 this is query start time in UNIX microseconds in uint64.
  • FE this tell us to read the next 8 bytes as uint64.
  • 91 00 B3 4A 28 86 05 00 this is query end time in UNIX microseconds in uint64.
  • FE this tell us to read the next 8 bytes as uint64.
  • D6 1F BA 14 4D 1F 23 AE this is query digest in uint64, but it needs to be separated into two uint32 and then it can be printed into hex sprintf("0x%X%X", n1, n2) == 0x14BA1FD6AE231F4D.
  • 0C this is the length of the actual query because it is less than or equal 0xFB, convert to uint64.
  • 2E 30 2E 31 3A 33 32 38 32 30 00 A5 this the actual query in ASCII.

Then we can go to the next line and repeat.

Decoding Message Parts Length

To decode part length, first we must take the first byte of the part. Then we check if:

  • It is less or equal than 0xFB. If so we take this byte as the message length.
  • It is equal to 0xFC. If so, we take 2 bytes as the message length.
  • It is equal to 0xFD. If so, we take 3 bytes as the message length.
  • It is equal to 0xFE. If so, we take 8 bytes as the message length.