dbus paths
Tank:
com.victronenergy.tank
/analogpinFunc
/Level 0 to 100%
/Remaining m3
/Status 0=Ok; 1=Disconnected; 2=Short circuited; 3=Unknown
/Capacity m3
/FluidType 0=Fuel; 1=Fresh water; 2=Waste water; 3=Live well; 4=Oil; 5=Black water (sewage)
/Standard 0=European; 1=USA
Note that the FluidType enumeration is kept in sync with NMEA2000 definitions.
Temperature:
com.victronenergy.temperature
/analogpinFunc
/Temperature degrees Celcius
/Status 0=Ok; 1=Disconnected; 2=Short circuited; 3=Reverse polarity; 4=Unknown
/Scale
/Offset
/TemperatureType 0=battery; 1=fridge; 2=generic