mbernson / hcpy

Python tool to talk to Home Connect appliances over the local network (no cloud required)

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

dishwasher installed in a kitchen

Interface with Home Connect appliances in Python

This is a very, very beta interface for Bosch-Siemens Home Connect devices through their local network connection. Unlike most IoT devices that have a reputation for very bad security, BSG seem to have done a decent job of designing their system, especially since they allow a no-cloud local control configuration. The protocols seem sound, use well tested cryptographic libraries (TLS PSK with modern ciphres) or well understood primitives (AES-CBC with HMAC), and should prevent most any random attacker on your network from being able to take over your appliances to mine cryptocurrency.

WARNING: This tool not ready for prime time and is still beta!

Setup

pip3 install -r requirements.txt

Install the Python dependencies; the sslpsk one is a little weird and we might need to revisit it later.

Authenticate to the cloud servers

laptop in a clothes washer with a display DoorState:Closed

hc-login $USERNAME $PASSWORD > config.json

The hc-login script perfoms the OAuth process to login to your Home Connect account with your usename and password. It receives a bearer token that can then be used to retrieves a list of all the connected devices, their authentication and encryption keys, and XML files that describe all of the features and options.

This only needs to be done once or when you add new devices; the resulting configuration JSON file should be sufficient to connect to the devices on your local network, assuming that your mDNS or DNS server resolves the names correctly.

Home Connect to MQTT

hc2mqtt config.json

This tool will establish websockets to the local devices and transform their messages into MQTT JSON messages. The exact format is likely to change; it is currently a thin translation layer over the XML retrieved from cloud servers during the initial configuration.

Dishwasher

laptop in a dishwasher

The dishwasher has a local HTTPS port open, although attempting to connect to the HTTPS port with curl results in a cryptic protocol error due to the non-standard cipher selection, ECDHE-PSK-CHACHA20-POLY1305. PSK also requires that both sides agree on a symetric key, so a special hacked version of sslpsk is used to establish the connection and then hand control to the Python websock-client library.

Example message published to homeconnect/dishwasher:

{
	"state":	"Run",
	"door":		"Closed",
	"remaining":	"2:49",
	"power":	true,
	"lowwaterpressure": false,
	"aquastop":	false,
	"error":	false,
	"remainingseconds": 10140
}
Full state information
{
	'AllowBackendConnection': False,
	'BackendConnected': False,
	'RemoteControlLevel': 'ManualRemoteStart',
	'SoftwareUpdateAvailable': 'Off',
	'ConfirmPermanentRemoteStart': 'Off',
	'ActiveProgram': 0,
	'SelectedProgram': 8192,
	'RemoteControlStartAllowed': False,
	'520': '2022-02-21T16:48:54',
	'RemoteControlActive': True,
	'AquaStopOccured': 'Off',
	'DoorState': 'Open',
	'PowerState': 'Off',
	'ProgramFinished': 'Off',
	'ProgramProgress': 100,
	'LowWaterPressure': 'Off',
	'RemainingProgramTime': 0,
	'ProgramAborted': 'Off',
	'547': False,
	'RemainingProgramTimeIsEstimated': True,
	'OperationState': 'Inactive',
	'StartInRelative': 0,
	'EnergyForecast': 82,
	'WaterForecast': 70,
	'ConnectLocalWiFi': 'Off',
	'SoftwareUpdateTransactionID': 0,
	'SoftwareDownloadAvailable': 'Off',
	'SoftwareUpdateSuccessful': 'Off',
	'ProgramPhase': 'Drying',
	'SilenceOnDemandRemainingTime': 0,
	'EcoDryActive': False,
	'RinseAid': 'R04',
	'SensitivityTurbidity': 'Standard',
	'ExtraDry': False,
	'HotWater': 'ColdWater',
	'TimeLight': 'On',
	'EcoAsDefault': 'LastProgram',
	'SoundLevelSignal': 'Off',
	'SoundLevelKey': 'Medium',
	'WaterHardness': 'H04',
	'DryingAssistantAllPrograms': 'AllPrograms',
	'SilenceOnDemandDefaultTime': 1800,
	'SpeedOnDemand': False,
	'InternalError': 'Off',
	'CheckFilterSystem': 'Off',
	'DrainingNotPossible': 'Off',
	'DrainPumpBlocked': 'Off',
	'WaterheaterCalcified': 'Off',
	'LowVoltage': 'Off',
	'SaltLack': 'Off',
	'RinseAidLack': 'Off',
	'SaltNearlyEmpty': 'Off',
	'RinseAidNearlyEmpty': 'Off',
	'MachineCareReminder': 'Off',
	'5121': False,
	'HalfLoad': False,
	'IntensivZone': False,
	'VarioSpeedPlus': False,
	'5131': False,
	'5134': True,
	'SilenceOnDemand': False
}

Clothes washer

laptop in a clothes washer

The clothes washer has a local HTTP port that also responds to websocket traffic, although the contents of the frames are AES-CBC encrypted with a key derived from HMAC(PSK,"ENC") and authenticated with SHA256-HMAC using another key derived from HMAC(PSK,"MAC"). The encrypted messages are send as binary data over the websocket (type 0x82).

Example message published to homeconnect/washer:

{
	"state": "Ready",
	"door": "Closed",
	"remaining": "3:48",
	"power": true,
	"lowwaterpressure": false,
	"aquastop": false,
	"error": false,
	"remainingseconds": 13680
}
Full state information
{
	'BackendConnected': False,
	'CustomerEnergyManagerPaired': False,
	'CustomerServiceConnectionAllowed': False,
	'DoorState': 'Open',
	'FlexStart': 'Disabled',
	'LocalControlActive': False,
	'OperationState': 'Ready',
	'RemoteControlActive': True,
	'RemoteControlStartAllowed': False,
	'WiFiSignalStrength': -50,
	'LoadInformation': 0,
	'AquaStopOccured': 'Off',
	'CustomerServiceRequest': 'Off',
	'LowWaterPressure': 'Off',
	'ProgramFinished': 'Off',
	'SoftwareUpdateAvailable': 'Off',
	'WaterLevelTooHigh': 'Off',
	'DoorNotLockable': 'Off',
	'DoorNotUnlockable': 'Off',
	'DoorOpen': 'Off',
	'FatalErrorOccured': 'Off',
	'FoamDetection': 'Off',
	'DrumCleanReminder': 'Off',
	'PumpError': 'Off',
	'ReleaseRinseHoldPending': 'Off',
	'EnergyForecast': 20,
	'EstimatedTotalProgramTime': 13680,
	'FinishInRelative': 13680,
	'FlexFinishInRelative': 0,
	'ProgramProgress': 0,
	'RemainingProgramTime': 13680,
	'RemainingProgramTimeIsEstimated': True,
	'WaterForecast': 40,
	'LoadRecommendation': 10000,
	'ProcessPhase': 4,
	'ReferToProgram': 0,
	'LessIroning': False,
	'Prewash': False,
	'RinseHold': False,
	'RinsePlus': 0,
	'SilentWash': False,
	'Soak': False,
	'SpeedPerfect': False,
	'SpinSpeed': 160,
	'Stains': 0,
	'Temperature': 254,
	'WaterPlus': False,
	'AllowBackendConnection': False,
	'AllowEnergyManagement': False,
	'AllowFlexStart': False,
	'ChildLock': False,
	'Language': 'En',
	'PowerState': 'On',
	'EndSignalVolume': 'Medium',
	'KeySignalVolume': 'Loud',
	'EnableDrumCleanReminder': True,
	'ActiveProgram': 0,
	'SelectedProgram': 28718
}

Coffee Machine

Image of the coffee machine from the Siemens website

The coffee machine needs a better mapping to MQTT messages.

Full state information
{
	'LastSelectedBeverage': 8217,
	'LocalControlActive': False,
	'PowerSupplyError': 'Off',
	'DripTrayNotInserted': 'Off',
	'DripTrayFull': 'Off',
	'WaterFilterShouldBeChanged': 'Off',
	'WaterTankEmpty': 'Off',
	'WaterTankNearlyEmpty': 'Off',
	'BrewingUnitIsMissing': 'Off',
	'SelectedProgram': 0,
	'MacchiatoPause': '5Sec',
	'ActiveProgram': 0,
	'BeverageCountdownWaterfilter': 48,
	'BeverageCountdownCalcNClean': 153,
	'RemoteControlStartAllowed': True,
	'EmptyDripTray': 'Off',
	'BeverageCountdownDescaling': 153,
	'EmptyDripTrayRemoveContainer': 'Off',
	'BeverageCounterRistrettoEspresso': 177,
	'AllowBackendConnection': True,
	'BeverageCounterHotWater': 37351,
	'RemindForMilkAfter': 'Off',
	'BeverageCounterFrothyMilk': 22,
	'BeverageCounterCoffeeAndMilk': 1077,
	'CustomerServiceRequest': 'Off',
	'4645': 0,
	'CoffeeMilkOrder': 'FirstCoffee',
	'BackendConnected': True,
	'BeverageCounterCoffee': 21,
	'Enjoy': 'Off',
	'UserMode': 'Barista',
	'PlaceEmptyGlassUnderOutlet': 'Off',
	'WaterTankNotInserted': 'Off',
	'PlaylistRunning': False,
	'BeverageCounterPowderCoffee': 9,
	'DemoModeActive': False,
	'CleanBrewingUnit': 'Off',
	'WaterHardness': 'Medium',
	'CloseDoor': 'Off',
	'EmptyMilkTank': 'Off',
	'SpecialRinsing': 'Off',
	'AllowConsumerInsights': False,
	'SwitchOffAfter': '01Hours15Minutes',
	'4681': 0,
	'LastSelectedCoffeeWorldBeverage': 20514,
	'BrightnessDisplay': 7,
	'CleanMilkTank': 'Off',
	'NotEnoughWaterForThisKindOfBeverage': 'Off',
	'ChildLock': False,
	'4666': 0,
	'Language': 'De',
	'MilkContainerConnected': 'Off',
	'SoftwareUpdateAvailable': 'Off',
	'LeaveProfilesAutomatically': True,
	'RemoveWaterFilter': 'Off',
	'OperationState': 'Inactive',
	'BeverageCounterHotMilk': 9,
	'4362': 0,
	'MilkTubeRemoved': 'Off',
	'DeviceIsToCold4C': 'Off',
	'SystemHasRunDry': 'Off',
	'DeviceShouldBeDescaled': 'Off',
	'PowerState': 'Standby',
	'DeviceShouldBeCleaned': 'Off',
	'DeviceShouldBeCalcNCleaned': 'Off',
	'BeanContainerEmpty': 'Off',
	'MilkStillOK': 'Off',
	'CoffeeOutletMissing': 'Off',
	'MilkReminder': 'Off',
	'RefillEmptyWaterTank': 'Off',
	'RefillEmptyBeanContainer': 'Off',
	'UnderOverVoltage': 'Off',
	'NotEnoughPomaceCapacityForThisKindOfBeverage': 'Off',
	'AdjustGrindSetting': 'Off',
	'InsertWaterFilter': 'Off',
	'FillDescaler': 'Off',
	'CleanFillWaterTank': 'Off',
	'PlaceContainerUnderOutlet': 'Off',
	'SwitchOffPower30sekBackOn': 'Off',
	'ThrowCleaningDiscInTheDrawer': 'Off',
	'RemoveMilkContainer': 'Off',
	'RemoveContainerUnderOutlet': 'Off',
	'MilkContainerRemoved': 'Off',
	'ServiceProgramFinished': 'Off',
	'DeviceDescalingOverdue': 'Off',
	'DeviceDescalingBlockage': 'Off',
	'CustomerServiceConnectionAllowed': False,
	'BeverageCountdownCleaning': 38,
	'ProcessPhase': 'None'
}

FRIDA tools

Moved to README-frida.md

About

Python tool to talk to Home Connect appliances over the local network (no cloud required)


Languages

Language:Python 100.0%