This code implements communication with the Eaton xComfort CKOZ-00/14 Communication stick (CI stick). The CI stick needs to be added into the network with CKOZ-00/13.

xComfort is a wireless European home automation system, using the 868,3MHz band. The system is regrettably closed source. This code was reverse engineered from a variety of sources, plus some initial inspiration from https://github.com/mifi/libxcomfort.

This code has been tested with and recognizes at least the following messages:

  • MSG_ON
  • MSG_OFF
  • MSG_UP_PRESSED
  • MSG_UP_RELEASED
  • MSG_DOWN_PRESSED
  • MSG_DOWN_RELEASED
  • MSG_STATUS

Furthermore, it can send on/off/dim%/start/stop messages to devices.

xComfort status messages are not routed and have no delivery guarantees. When status messages are lost, lights may for instance be switched on and off, and you will never know. Careful placement of the USB stick is important, so that it can see these messages, however, in my case, some messages are still lost. Polling devices in a round robin fashion might provide a somewhat clumsy workaround for this, but that's presently not implemented. Newer xComfort devices support "extended status messages" that are routed, but I have no such devices and don't know if they work with this software.

The code has been written without any kind of documentation from Eaton, and may not follow their specifications.

The CKOZ-00/14 doesn't expose or know which devices hide behind the datapoints. It's the user's responsibility to send correct messages to the datapoints; this code does no validation of messages sent. However, the devices appear to ignore messages they don't understand. MRF can export a datapoint to device map, but I have not added support for that, as the benefits were limited.

A simple application for forwarding events to and from an MQTT server is provided. This can be used eg. to interface an xComfort installation with homebridge-mqttswitch or Home Assistant, with a little imagination. The application subscribes to the topics:

"xcomfort/+/set/dimmer" (accepts values from 0-100)
"xcomfort/+/set/switch" (accepts true or false)
"xcomfort/+/set/shutter" (accepts down, up or stop)
"xcomfort/+/set/requeststatus" (value is ignored)

and publishes on the topics:

"xcomfort/[datapoint number]/get/dimmer" (value from 0-100)
"xcomfort/[datapoint number]/get/switch" (true or false)
"xcomfort/[datapoint number]/get/shutter" (up, down or stop)

Sending true to topic xcomfort/1/set/switch will send a message to datapoint 1 to turn on. This will work for both switches and dimmers. Sending the value 50 to xcomfort/1/set/dimmer will send a message to datapoint 1 to set 50% dimming. This will work only for dimmers.

Likewise, xcomfort/1/get/dimmer and xcomfort/1/get/switch will be set to the value reported by the dimmer/switch, if and when datapoint 1 reports changes. Subscribe to the topic that's relevant for the device that's actually associated with the datapoint. Status reports are not routed in the xComfort network, so if your CI stick is not able to hear all devices, these status messages will be lost.

By sending any message to the topic xcomfort/1/set/requeststatus, the application will ask datapoint 1 to report its status.

WARNING: The firmware "RF V2.08 - USB V2.05" is buggy and will read status reports from dimmers incorrectly as always off. This is resolved in the later "RF V2.10 - USB V2.05" firmware.

Copyright 2016 Karl Anders Øygard. All rights reserved. Use of this source code is governed by a BSD-style license that can be found in the LICENSE file. The code for shutters and more was contributed by Hans Karlinius.