ewencedr / cs-fmu-mapper

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

CS-FMU-Mapper

Installation

    > $ conda create -n cs-fmu-mapper python=3.10
    > $ conda activate cs-fmu-mapper
    > $ conda install -c conda-forge pyfmi
    > $ pip3 install -r requirements.txt

Executing Example

    > $ python main.py -c example/config.yaml

Configuration

Configuration is done in YAML format. The configuration file can also be formatted as JSON but YAML is recommended as it supports commenting. A detailed commented example configuration is given here.

The configuration basically defines simulation components of type plc, fmu, logger and/or scenario. Each components' section defines ouputVars and/or inputVars by specifying their component-specific access string called nodeID, e.g. the OPCUA NodeID for a plc component or the CSV column name of a scenario component. Configuration of scenario and logger components are optional. Configuration of plc component is also optional but only makes sense if there is at least a scenario or another custom component configured which interacts with the fmu.

Besides the component configuration, there is a Mapping section where the Mapping from outputVars to inputVars is configured. For a detailed explanation see the example config. The simulation will be performed in steps. If a mapping is configured as preStepMapping the mapping will be done before simulation step execution. Consequently, when a mapping is configured as postStepMapping the mapping will be done afterwards.

If there is a plc component configured the plc will be the simulation master and will trigger each simulation step. If there is no plc configured the software will simulate standalone with the configured step size timeStepPerCycle configured in the Mapping section. If every component signalizes that it is finished then every component will be notified that the simulation is finished. In standalone mode, the simulation will then finalize itself. In plc master mode the plc should react accordingly and should initiate the termination of the program.

Usage

The example can be executed via the following command:

> $ python main.py -c example/config.yaml

Implementing new Components

A custom simulation component can be created by inheriting from SimulationComponent. The inherited class should define a class variable type which value determines the value of the type field in the configuration file. Also, all abstract methods from SimulationComponent have to be implemented. Place the custom class inside the subpackage components. The constructor should take two arguments the corresponding section of the configuration as dict and a name. A minimal simulation component could look like:

from simulation_component import SimulationComponent

class CustomComponent(SimulationComponent):
    type = "custom"

    def __init__(self, config, name):
        pass

    def do_step(self, t, dt):
        pass

SimulationComponent buffers the mapped input and output values in two dictionaries. One for input and the other for output values. There are getters and setters for getting and setting single values or the whole dict. The two dicts shall only be accessed by those getters and setters:

    # for setting/getting the while input dict
    def get_input_values(self)
    def set_input_values(self, new_val)
    # for setting/getting single values in the input dict
    def get_input_value(self, name)
    def set_input_value(self, name, new_val)
    # for setting/getting the whole output dict
    def get_output_values(self)
    def set_output_values(self, new_val)
    # for setting/getting single values in the output dict
    def get_output_value(self, name)
    def set_output_value(self, name, new_val)

The implementation of doStep() should read the component's output values and write them into the SimulationComponents output buffer via the above-mentioned methods. Accordingly, it should read the input buffer and write them to the component inputs. The name arguments of the above methods represent the configured unique keys of the outputVar/inputVar section of the component. If no outputVar or inputVar are configured the according getters and setters raise a NotImplementedError.

Optionally the component can implement the following methods:

    def is_finished(self)
    def notify_simulation_finished(self)
    def finalize(self)

If the component shall affect the end of a simulation its is_finished() method should return false as long as it isn't finished. The default return value if not implemented is true. As soon as every component finishes its execution the notify_simulation_finshed() callback is called. The finalize() callback is called shortly before the termination of the program. Any open connections could be closed here, or occupied memory could be freed here for example.

For logging purposes, these three methods can be used:

    def log_info(self, msg)
    def log_debug(self, msg)
    def log_warning(self, msg)

Known Issues

TODOs

  • Make do_step() method async
  • Add a start_component() method to the SimulationComponent class that automatically does the async initialization of the component. This method should be called in the main loop of the program.
  • Make sure that AbstractOPCUA client uses its own logger and not the SimulationComponent logger

About