Automated start sequencer for the Creekfleet sailing group.
By default, runs the following sequence for each of the number of requested starts:
Horns | Time to start |
---|---|
3 long | 3:00 |
2 long | 2:00 |
1 long, 3 short | 1:30 |
1 long | 1:00 |
3 short | 0:30 |
2 short | 0:20 |
1 short | 0:10 |
1 short | 0:05 |
1 short | 0:04 |
1 short | 0:03 |
1 short | 0:02 |
1 short | 0:01 |
1 long | START |
Also has a mode selectable during idle operation for the ISAF Rule 26 start:
Horns | Time to start |
---|---|
1 short | 5:00 |
1 short | 4:00 |
1 long | 1:00 |
1 short | START |
Function | Arduino Pin |
---|---|
Horn | D12 |
Compressor | D11 |
Pressure Gauge | D35 (A16) |
UP.LED | D24 |
UP.Switch | D25 (active low) |
DOWN.LED | D26 |
DOWN.Switch | D27 (active low) |
SELECT.LED | D28 |
SELECT.Switch | D29 (active low) |
BACK.LED | D30 |
BACK.Switch | D31 (active low) |
LCD.VO | A22 (DAC1) |
LCD.RS | D13 |
LCD.RW | D14 |
LCD.E | D15 |
LCD.DB0 | D16 |
LCD.DB1 | D17 |
LCD.DB2 | D18 |
LCD.DB3 | D19 |
LCD.DB4 | D20 |
LCD.DB5 | D21 |
LCD.DB6 | D22 |
LCD.DB7 | D23 |
LCD.Red BL | D36 (PWM) |
LCD.Green BL | D38 (PWM) |
LCD.Blue BL | D37 (PWM) |