RadJKW / rpi_Instruction_Display

Middle man to recieve UART messages from Z80 computer and then open web-svr pdf viewer

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

rpi_Instruction_Display

Middle man to recieve UART messages from Z80 computer and then open web-svr pdf viewer TASKS: • Handle Codes: All codes are transmitted in ASCII and are ended with a Carriage Return character (0A hex).

    GENERAL CODES:
    CI		Coil Information, followed by the 13-digit coil number and the division the coil is for.
        Sent on boot-up if there is an active coil.
        Format:  CI,nnnnnnnnnnnnn,n
        Example:  CI,0050123456789,1
    NC		New Coil, followed by the 13-digit coil number and the division the coil is for.
        Sent when a new coil spec is downloaded or winding is started on a new coil.
        Format:  NC,nnnnnnnnnnnnn,n
        Example:  NC,0050123456789,3
    NW		New Winding, followed by winding type, material type, and conductor width.
        Sent when a new winding is started.
        Format:  NW,XX,XX,nn.nnnn
    where winding type is PA (Paper), LV (Low Voltage), or HV (High Voltage)
    and material type is PM (Paper), WC (Wire), or SC (Sheet)
        Example:  NW,HV,WC,00.1250
    RS		Run Screen, followed by winding type, material type, and conductor width.
        Sent when the operator changes to the Run Screen.
        Format:  RS,XX,XX,nn.nnnn
          where winding type is PA (Paper), LV (Low Voltage), or HV (High Voltage)
          and material type is PM (Paper), WC (Wire), or SC (Sheet)
        Example:  RS,LV,SC,08.2500
    DE		Data Entry screen.  Sent when the operator changes to the winding data screen.
    FC		Finished Coil.  Sent when a coil is completed.

    “ALMOST” TURN STOPS:
    AAD		Almost at an Annular Duct stop
    ACX		Almost at a Crepe Extension Paper stop
    ADS		Almost at an End Duct stop
    ALE		Almost at a Layer End/End of Layer stop
    APX		Almost at a Plain Extension Paper stop
    ATB		Almost at a Tab Break/Section Break stop
    ATS		Almost at a Tap stop
    ATT		Almost at a Total Turns stop
    AXP		Almost at an Extra Paper stop
    TURN STOPS:
    AD		Annular Duct stop
    CX		Crepe Extension Paper stop
    DS		End Duct stop
    LE		Layer End/End of Layer stop
    PX		Plain Extension Paper stop
    TB		Tab Break/Section Break stop
    TS		Tap stop
    TT		Total Turns stop
    XP		Extra Paper stop