Ecograph OPC Server v0.11
Classic OPC Server on Ecograph. Included 486 tags (122 rVal tags). Include all data,information and settings tags. Working with device with number 01-99. Allow include only needed tags, by configurate type and number of channal in config file. Support configuration from .ini file. Server based on lightopc v0.88
After install software you must register server with key /r. You also may unregistered server with key /u. For example opc.exe /r or opc.exe /u. Show help key /?.
v0.11 build 59 0 fixed bug with show incorrect status on all tags if last tag in list is uncertain.
- add remaining settings tags.
- add data channal tags.
- add "Integrator" option in config file, include/exclude integration data tags.
- add "Digital" option in config file, include/exclude digital channal data tags.
- add "Analog" option in config file, include/exclude analog channal data tags. 0 fixed unknown bug, when server wrong count tags.
v0.10 build 43
- add ability to switch intellect from .ini file.
- add digital input settings tag.
- add intellect system on digital inputs tags.
- add ability switch on/off rVal tags.
- add new section .ini file "Server".
- add ability write comment to .ini file = total device scanned on bus increased to 99.
v0.09 build 103
- remove not used temporary data equation.
- add intelegence analyze analog data system. check analog inputs only when inputs has been used (active).
- add prioritet system. each tag now have a attribute named "priority", which show frequency request this tag. maximum priority is 1, minimum 65000.
- significantly increase frequency of processing tag.
- add new 280 tags on another 5 channal.
- add ability to configurate connection speed from .ini file.
v0.08 build 118
- quantity of tags increased to 112 (included 24 rVal and 5 unknown). = fixed possible bug with memory overflow on find token in rVal tags. 0 fixed bug when opc quality is good, when answer on command do not recieve. 0 fixed bug opc quality is still good, when device is temporary not answer. = possible quantity tags increased to 500. 0 fixed bug on show bad status on tags recivied on version commands. 0 fixed bug with wrong access rights on some tags.
v0.07 build 119
- add new type of tags (rVal) - real value tags. readable tags is data from correspondly tags throw enumerated table with links between real value and protocol data.
- add full support rVal tags. add and register tags. read and form tag data.
- add 18 new basic settings tags and correspondly 8 rVal tags.
v0.06 build 57
- added 11 settings tag recieved on various read command.
- add support variant type unsigned int;
- add intelligent conversion and round from type (unsigned) speed on server to enumerated string in device;
- add intelligent conversion from type (string) unit feed on server to enumerated string in device; 0 fixed wrong "write success" text in output log; 0 fixed bug with device data buffer overflow; 0 fixed wrong "add command" text in output log; 0 fixed bug with use wrong buffer on "no scan" command;
- add new log events on error in read, write and version command; 0 fixed possible problem in define success result on recieve answer from device;
- add tag hierarchy;
v0.05 build 36
- added 12 no information tag recieved on version command.
- global change write function.
- added device identificator tag (read/write tag).
Information/Programme Information/Version Information/CPU number Settings/Identificator Settings/Current date Settings/Current time Settings/Date WT>ST Settings/Time WT>ST Settings/Date ST>WT Settings/Time ST>WT Settings/Access Code Settings/Feed Unit Settings/Normal feed speed Settings/Active feed speed Settings/Channal Identificator Settings/Channal Identificator (rVal) Settings/Group Identificator
Settings/Switch time Settings/Switch time (rVal) Settings/Temperature unit Settings/Temperature unit (rVal)
Settings/View/Grid Lines Settings/View/Grid Lines (rVal) Settings/View/Pen Settings/View/Pen (rVal) Settings/View/Show Pen Settings/View/Show Pen (rVal)
Settings/Floppy/Warning Settings/Floppy/Relay Settings/Floppy/Relay (rVal) Settings/Floppy/Quota Settings/Floppy/Quota (rVal)
Settings/Screensaver/Screensaver Settings/Screensaver/On time Settings/Screensaver/Off time
Other/Serial interface/Device address Other/Serial interface/Interface type Other/Serial interface/Interface type (rVal) Other/Serial interface/Speed Other/Serial interface/Speed (rVal) Other/Serial interface/Parity Other/Serial interface/Parity (rVal) Other/Serial interface/Stop bits Other/Serial interface/Stop bits (rVal) Other/Serial interface/Data bits Other/Serial interface/Data bits (rVal) Other/Memory/Work regim Other/Memory/Work regim (rVal)
Service/Common/Software version Service/Common/Last switch on Service/Common/Last C-instruction Service/Common/Setup Service/Common/Show address Service/Common/CPU number Service/Common/Work time total Service/Common/Work time LCD
Service/Running Costs/Money unit Service/Running Costs/Metre cost Service/Running Costs/Pen cost Service/Running Costs/Reset
Information/Module board 1 Information/Module board 2 Information/Digital IO Information/RS485 Information/RS485-Profibus Information/Data memory Information/Internal memory Information/Integration Information/Digital board 1 Information/Digital board 2 Information/Math channel Information/Data interface
Analog channal x Analog channal x (intermediate) Analog channal x (daily) Analog channal x (monthly) Analog channal x (yearly)
Analog input/x/Type Analog input/x/Type (rVal) Analog input/x/Channal ID Analog input/x/Measure Unit Analog input/x/Decimal point Analog input/x/Decimal point (rVal) Analog input/x/Begin diapason Analog input/x/End diapason Analog input/x/Begin undiapason Analog input/x/End undiapason Analog input/x/Damping filter Analog input/x/Termo compensation value Analog input/x/Termo compensation Analog input/x/Termo compensation (rVal) Analog input/x/Copy settings Analog input/x/Registration type Analog input/x/Registration type (rVal) Analog input/x/Wire type Analog input/x/Wire type (rVal) Analog input/x/Diapason indetion/Begin Analog input/x/Diapason indetion/End Analog input/x/Integration/Integration Analog input/x/Integration/Integration (rVal) Analog input/x/Integration/Time basis Analog input/x/Integration/Time basis (rVal) Analog input/x/Integration/Integration unit Analog input/x/Integration/Show sequence Analog input/x/Integration/Show sequence (rVal) Analog input/x/Integration/Maximum value Analog input/x/Integration/Coefficient
Analog input/x/Valuepoint 1/Valuepoint type Analog input/x/Valuepoint 1/Valuepoint type (rVal) Analog input/x/Valuepoint 1/Value Analog input/x/Valuepoint 1/Hysteresis Analog input/x/Valuepoint 1/Pause time Analog input/x/Valuepoint 1/Relay on Analog input/x/Valuepoint 1/Relay on (rVal) Analog input/x/Valuepoint 1/Switching on message Analog input/x/Valuepoint 1/Switching off message Analog input/x/Valuepoint 1/Show message Analog input/x/Valuepoint 1/Show message (rVal) Analog input/x/Valuepoint 1/Feeding change Analog input/x/Valuepoint 1/Feeding change (rVal)
Analog input/x/Valuepoint 2/Valuepoint type Analog input/x/Valuepoint 2/Valuepoint type (rVal) Analog input/x/Valuepoint 2/Value Analog input/x/Valuepoint 2/Hysteresis Analog input/x/Valuepoint 2/Pause time Analog input/x/Valuepoint 2/Relay on Analog input/x/Valuepoint 2/Relay on (rVal) Analog input/x/Valuepoint 2/Switching on message Analog input/x/Valuepoint 2/Switching off message Analog input/x/Valuepoint 2/Show message Analog input/x/Valuepoint 2/Show message (rVal) Analog input/x/Valuepoint 2/Feeding change Analog input/x/Valuepoint 2/Feeding change (rVal)
Digital channal x
Digital input/x/Input function Digital input/x/Input function (rVal) Digital input/x/Identificator Digital input/x/Action Digital input/x/Action (rVal) Digital input/x/Label log 1 Digital input/x/Label log 0 Digital input/x/Message on 0->1 Digital input/x/Message on 1->0 Digital input/x/Message text Digital input/x/Message text (rVal)