OITApps / HT81xConfig

Custom netsapiens config for Grandstream HT-81x devices

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

Custom Template for Grandstream HT-81x ATAs

The following is a custom template for the Grandstream HT-81x series of ATAs. This has been tested with the HT-812 and HT-814 on firmware 10.0.25.5. Line configurations have been configured for up to 4 independent lines. You can add Hunt Groups via additional overrides.

Instructions

Create Custom Format

  1. In your NDP, navigate to System, then Files and Firmware
  2. Upload grandstreamHT81x.xml
  3. Click on System, then Custom Definitions
  4. Click Add
  5. Format Name: Grandstream HT-81x
  6. Template: grandstreamHT81x.xml
  7. Click Create

Note Overrides

You will need to modify and add these overrides per device definition. Replace the values within the quotation marks for use in the next section

P2="secure web password" P133="0 fixed buffer, 1 adaptive" P231="Device Mode. 0 -NAT Router, 1 - Bridge" P824="disable LEC" P192="firmware path without protocol" P237="provisioning url without protocol" P1650="web access mode 0 - HTTPS, 1 - HTTP, 2 - Disabled"

Create Grandstream HT-812

  1. Click on System, then Device Definitions
  2. Click Add
  3. Brand: Grandstream
  4. Model: HT-812
  5. Type: Device
  6. NDP Code Structure: Grandstream HT-81x
  7. Number of Phone Lines: 2
  8. Resync Enabled: yes
  9. Show in portal: yes
  10. Overrides: Add overrides from previous section
  11. Click Create

Create Grandstream HT-814

  1. Click on System, then Device Definitions
  2. Click Add
  3. Brand: Grandstream
  4. Model: HT-814
  5. Type: Device
  6. NDP Code Structure: Grandstream HT-81x
  7. Number of Phone Lines: 4
  8. Resync Enabled: yes
  9. Show in portal: yes
  10. Overrides: Add overrides from previous section
  11. Click Create

Summary

The models will now be available for provisioning from the Manager Portal as a device.

About

Custom netsapiens config for Grandstream HT-81x devices

License:MIT License