Can I use a Jameco 112366 with board 1.4 rev3?
rb28z2 opened this issue · comments
Kanchana M commented
As the title says, I have a board version 1.4 rev 3, but according to the firmware and documentation, I can only use a Jameco 157041: https://github.com/CircuitSetup/Split-Single-Phase-Energy-Meter/blob/master/Software/EmonESP/src/energy_meter.h#L63-L64
Is this actually the case or can I use a Jameco 112366 (essentially identical to the 15704 but is a 1.5A instead of a 1A) with a rev3 board?
John commented
Sorry I didn't see your question sooner.
Yes, that transformer can be used. I would recommend calibrating it to the meter so you get accurate readings.