本リポジトリでは、暖冷房負荷計算の開発を行っています。
You can run a sample that executes the following command.
$ git clone git@github.com:BRI-EES-House/heat_load_calc.git
$ cd heat_load_calc
$ mkdir out
$ python3 src/heat_load_calc/heat_load_calc.py src/heat_load_calc//example/data_example1/mid_data_house.json -o out
The files will be generated in the out
folder.
See docs/data_spec/spec_mid_data_house.csv
and create a file.
The following file will be generated.
Save the file with the calculation conditions for later checking.
- mid_data_house.json ... 住宅計算条件JSONファイル
These files will be generated when the --generate-schedule-only
flag is specified.
- mid_data_local_vent.csv ... ステップnの室iにおける局所換気量
- mid_data_heat_generation.csv ... ステップnの室iにおける内部発熱
- mid_data_moisture_generation.csv ... ステップnの室iにおける人体発湿を除く内部発湿
- mid_data_occupants.csv ... ステップnの室iにおける在室人数
- mid_data_ac_demand.csv ... ステップnの室iにおける空調需要
This file will be generated when the --generate-weather-only
flag is specified.
- weather.csv ... 気象データ
- result_detail_a.csv ... 15分ごとの計算結果(簡易版)(CSV)
- result_detail_i.csv ... 15分ごとの計算結果(詳細版)(CSV)
See docs/data_spec/spec_core_output_detail.csv
for result_detail_i.csv
.
-o=<output-folder>
... Specifies the output folder. If not specified, the output will be in the current folder.
--generate-weather-only
... Execute only the generation of weather data. It does not perform load calculations.
--generate-schedule-only
... Executes only schedule generation. It does not perform load calculations.
--load-weather=<weather-folder>
... Loads a weather file from a specified folder without generating a schedule.
--load-schedule=<schedule-folder>
... Loads schedule files from a specified folder without generating schedules.
--schedule_data_folder_path=<schedule-folder>
... Specify the schedule folder, where schedule files ares set.
Normally, the schedules are created automatically based on the total floor area.
However, when specifying the schedules without using the automatically created one, this path is needed to be specify.
https://heat-load-calc-document.readthedocs.io/ja/latest/
sphinx-build -b html docs/source/ dist
python3 -m http.server --directory dist 8080
See http://localhost:8080
=== 以下、旧文章(修正中) ===
外皮に関する入力情報の変換の仕方について記述しています。
外皮に関する入力情報として、入力情報の多さ等の観点から、下記のようにいくつかのレベルを設定しています。 なお、用途別の床面積については、下記のレベルに関わらず、すべての段階において入力されるとしています。
外皮の簡易計算法における入力情報 屋根・天井、壁、床、開口部といった部位の種類ごとにU値やη値が入力される。
部位ごとの断熱・日射熱取得性能が入力される。
Lv.2の情報に加えて、部位ごとに、その部位が接する空間用途(主たる居室、その他の居室、非居室、床下)が入力される。
Lv.3の情報に加えて、内壁の面積や熱物性値の情報を持つ。
熱バランスを室用途ごとに集約した、簡易熱負荷計算に必要な入力情報である。
設計実務者は、LV.1~LV.3までの入力方法を選択して入力する。