[BUG] PRUSA_AIO_THERMISTOR_GENERIC_100K
mojamuto opened this issue · comments
Did you test the latest prusa-aio-bugfix-2.1.x
code?
Yes, and the problem still exists.
Bug Description
When I select PRUSA_AIO_THERMISTOR_GENERIC_100K it doesn't compile and gives the following error:
Marlin/src/module/temperature.cpp:329:14: error: static assertion failed: HEATER_0_MAXTEMP (310) is too high for thermistor_1.h with HOTEND_OVERSHOOT=15.
selecting PRUSA_AIO_THERMISTOR_STOCK_SEMITEC_104NT compiles without problems
I just modified the file Prusa_AIO_Configuration.h
Prusa_AIO_Configuration.h.zip
Bug Timeline
New bug
Expected behavior
compile the firmware
Actual behavior
does not compile and gives the following error:
Marlin/src/module/temperature.cpp:329:14: error: static assertion failed: HEATER_0_MAXTEMP (310) is too high for thermistor_1.h with HOTEND_OVERSHOOT=15.
Steps to Reproduce
- clone repository
- Open vscode
- Modify Prusa_AIO_Configuration.h
- compile
Version of PrusaAIO Firmware
PRUSA_AIO_VERSION 20230520
Electronics
skr 1.4
Add-ons
No response
Bed Leveling
ABL Bilinear mesh
Your Slicer
PrusaSlicer
Host Software
SD Card (headless)
Don't forget to include
- A ZIP file containing your
Prusa_AIO_Configuration.h
.
Additional information & file uploads
No response
Thanks for the report!
I've patched this & rebased code on the latest upstream bugfix-2.1.x
, so it will now successfully compile when PRUSA_AIO_THERMISTOR_GENERIC_100K
is enabled.
tested and working thank you very much