arun912-ux opened this issue · comments

Hi.
I'm having a problem with BLUE PILL RTC in LSE_CLOCK. Time is not changing. It keeps the same time.
Clock is ticking in LSI_CLOCK but resets when power is down.

My code is

#include <STM32RTC.h>

/* Get the rtc object */
STM32RTC& rtc = STM32RTC::getInstance();

/* Change these values to set the current initial time */
const byte seconds = 0;
const byte minutes = 50;
const byte hours = 16;

/* Change these values to set the current initial date */
/* Monday 15th June 2015 */
const byte weekDay = 6;
const byte day = 18;
const byte month = 7;
const byte year = 20;

void setup()
{
  Serial.begin(115200);

  pinMode(PC13, OUTPUT);
  digitalWrite(PC13,0);
   
  // Select RTC clock source: LSI_CLOCK, LSE_CLOCK or HSE_CLOCK.
  // By default the LSI is selected as source.
  rtc.setClockSource(STM32RTC::LSE_CLOCK);

  rtc.begin(); // initialize RTC 24H format
//
  // Set the time
  rtc.setHours(hours);
  rtc.setMinutes(minutes);
  rtc.setSeconds(seconds);

//  Set the date
  rtc.setWeekDay(weekDay);
  rtc.setDay(day);
  rtc.setMonth(month);
  rtc.setYear(year);

  // you can use also
  //rtc.setTime(8, 50, 0);         // hours, minutes, seconds
  //rtc.setDate(6, 18, 7, 20);       // weekday, day, month, year
}

void loop()
{
  // Print date...
  print2digits(rtc.getDay());
  Serial.print(" - ");
  print2digits(rtc.getMonth());
  Serial.print(" - ");
  print2digits(rtc.getYear());
  Serial.print("  ");

  // ...and time
  print2digits(rtc.getHours());
  Serial.print(":");
  print2digits(rtc.getMinutes());
  Serial.print(":");
  print2digits(rtc.getSeconds());
  Serial.print("   ");
  Serial.print(rtc.getWeekDay());
  Serial.println();
  
  digitalWrite(PC13,!digitalRead(PC13));
  
  delay(1000);
}



void print2digits(int number) {
  if (number < 10) {
    Serial.print("0"); // print a 0 before if the number is < than 10
  }
  Serial.print(number);
}

Help me please.

Hello,
I observed the same issue - RTC is not working when source is LSE_CLOCK.

I am using the RTC_Tests (from STM32duino examples) with BluePill board.
LSI_CLOCK and HSE_CLOCK work, but LSE_CLOCK not - exactly not always.

I observed that when LSE is selected just after power up then it is not working.
When I first select the HSE then reset board by button and select LSE then it is working...

Serial Monitor output to show this behavior:

16:39:50.242 -> Select clock Source:
16:39:50.242 -> 1- LSI_CLOCK
16:39:50.242 -> 2- LSE_CLOCK
16:39:50.242 -> 3- HSE_CLOCK
16:39:50.242 ->
16:39:50.242 -> Enter number [1-3] 2
16:39:55.688 -> Test will use LSE_CLOCK
16:39:55.688 -> Testing asynchronous and synchronous prescaler setting
16:39:55.688 -> Async/Sync for default LSI clock: 0/0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - LSE not working - reset after 40 seconds
16:40:25.251 -> Select clock Source:
16:40:25.251 -> 1- LSI_CLOCK
16:40:25.251 -> 2- LSE_CLOCK
16:40:25.251 -> 3- HSE_CLOCK
16:40:25.251 ->
16:40:25.251 -> Enter number [1-3] 2
16:40:32.918 -> Test will use LSE_CLOCK
16:40:32.918 -> Testing asynchronous and synchronous prescaler setting
16:40:32.918 -> Async/Sync for default LSI clock: 0/0
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - LSE still not working - reset
16:41:17.253 -> Select clock Source:
16:41:17.253 -> 1- LSI_CLOCK
16:41:17.253 -> 2- LSE_CLOCK
16:41:17.253 -> 3- HSE_CLOCK
16:41:17.253 ->
16:41:17.253 -> Enter number [1-3] 3
16:41:24.750 -> Test will use HSE_CLOCK
16:41:24.750 -> Testing asynchronous and synchronous prescaler setting
16:41:24.750 -> Async/Sync for default LSI clock: 0/0
16:41:24.750 -> Async/Sync for selected clock: 0/0
16:41:24.750 -> User Async/Sync set to 99/9999: 0/0
16:41:24.750 -> 08/05/20 15:06:22
16:41:25.746 -> 08/05/20 15:06:22
16:41:26.741 -> 08/05/20 15:06:23
16:41:27.737 -> 08/05/20 15:06:24
16:41:28.733 -> 08/05/20 15:06:25
16:41:29.728 -> 08/05/20 15:06:26
16:41:30.724 -> 08/05/20 15:06:27
16:41:31.720 -> 08/05/20 15:06:28
16:41:32.749 -> 08/05/20 15:06:29
16:41:33.744 -> 08/05/20 15:06:30
16:41:34.741 -> User Async/Sync reset use the computed one: 0/0
16:41:34.741 -> Testing date and time
16:41:34.741 -> 24H format, new year
16:41:34.741 -> 12/31/17 23:59:56
16:41:35.736 -> 12/31/17 23:59:56
16:41:36.730 -> 12/31/17 23:59:57
16:41:37.724 -> 12/31/17 23:59:58
16:41:38.720 -> 12/31/17 23:59:59
16:41:39.748 -> 01/01/18 00:00:00
16:41:40.744 -> 01/01/18 00:00:01
16:41:41.740 -> 01/01/18 00:00:02
16:41:42.735 ->
16:41:42.735 -> Using Epoch API, set to Jan 1, 2016
16:41:42.735 -> Unix time = 1451606400
16:41:42.735 -> Seconds since Jan 1 2000 = 504921600
16:41:42.735 -> 01/01/16 00:00:00
16:41:43.730 -> Unix time = 1451606400
16:41:43.730 -> Seconds since Jan 1 2000 = 504921600
16:41:43.730 -> 01/01/16 00:00:01
16:41:44.726 -> Unix time = 1451606401
16:41:44.726 -> Seconds since Jan 1 2000 = 504921601
16:41:44.726 -> 01/01/16 00:00:02
16:41:45.721 -> Unix time = 1451606402
16:41:45.721 -> Seconds since Jan 1 2000 = 504921602
16:41:45.721 -> 01/01/16 00:00:03
16:41:46.716 -> Unix time = 1451606403
16:41:46.716 -> Seconds since Jan 1 2000 = 504921603
16:41:46.716 -> 01/01/16 00:00:04
16:41:47.745 -> Unix time = 1451606404
16:41:47.745 -> Seconds since Jan 1 2000 = 504921604
16:41:47.745 -> 01/01/16 00:00:05
16:41:48.741 -> Unix time = 1451606405
16:41:48.741 -> Seconds since Jan 1 2000 = 504921605
16:41:48.741 -> 01/01/16 00:00:06
16:41:49.736 -> Unix time = 1451606406
16:41:49.736 -> Seconds since Jan 1 2000 = 504921606
16:41:49.736 -> 01/01/16 00:00:07
16:41:50.733 ->
16:41:50.733 -> Testing alarm
16:41:50.733 ->
16:41:50.733 -> Every month
16:41:50.733 -> 08/05/20 15:06:22 05 15:06:27
16:41:51.729 -> 08/05/20 15:06:22 05 15:06:27
16:41:52.724 -> 08/05/20 15:06:23 05 15:06:27
16:41:53.720 -> 08/05/20 15:06:24 05 15:06:27
16:41:54.716 -> 08/05/20 15:06:25 05 15:06:27
16:41:55.745 -> 08/05/20 15:06:26 05 15:06:27
16:41:56.741 -> 08/05/20 15:06:27 05 15:06:27
16:41:56.741 -> Alarm Match MATCH_DHHMMSS
16:41:57.736 -> 09/05/20 15:06:18 05 15:06:27
16:41:58.731 -> 09/05/20 15:06:19 05 15:06:27
16:41:59.726 -> 09/05/20 15:06:20 05 15:06:27
16:42:00.721 -> 09/05/20 15:06:21 05 15:06:27
16:42:01.717 -> 09/05/20 15:06:22 05 15:06:27
16:42:02.746 -> 09/05/20 15:06:23 05 15:06:27
16:42:03.742 -> 09/05/20 15:06:24 05 15:06:27
16:42:04.738 -> 09/05/20 15:06:25 05 15:06:27
16:42:05.734 -> 09/05/20 15:06:26 05 15:06:27
16:42:06.731 -> 09/05/20 15:06:27 05 15:06:27
16:42:06.731 -> Alarm Match MATCH_DHHMMSS
16:42:07.727 -> 10/05/20 15:06:18 05 15:06:27
16:42:08.722 -> 10/05/20 15:06:19 05 15:06:27
16:42:09.718 -> 10/05/20 15:06:20 05 15:06:27
16:42:10.747 ->
16:42:10.747 -> Alarm disabled. Printing each 10s.
16:42:10.747 -> 08/05/20 15:06:22
16:42:20.734 -> 08/05/20 15:06:31
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - reset after all HSE tests
16:42:26.329 -> Select clock Source:
16:42:26.329 -> 1- LSI_CLOCK
16:42:26.329 -> 2- LSE_CLOCK
16:42:26.329 -> 3- HSE_CLOCK
16:42:26.329 ->
16:42:26.329 -> Enter number [1-3] 2
16:42:33.973 -> Test will use LSE_CLOCK
16:42:33.973 -> Testing asynchronous and synchronous prescaler setting
16:42:33.973 -> Async/Sync for default LSI clock: 0/0
16:42:34.272 -> Async/Sync for selected clock: 0/0
16:42:34.272 -> User Async/Sync reset use the computed one: 0/0
16:42:34.272 -> Testing date and time
16:42:34.272 -> 24H format, new year
16:42:34.272 -> 12/31/17 23:59:56
16:42:35.268 -> 12/31/17 23:59:56
16:42:36.264 -> 12/31/17 23:59:57
16:42:37.261 -> 12/31/17 23:59:58
16:42:38.257 -> 12/31/17 23:59:59
16:42:39.253 -> 01/01/18 00:00:00
16:42:40.249 -> 01/01/18 00:00:00
16:42:41.245 -> 01/01/18 00:00:01
16:42:42.274 ->
16:42:42.274 -> Using Epoch API, set to Jan 1, 2016
16:42:42.274 -> Unix time = 1451606400
16:42:42.274 -> Seconds since Jan 1 2000 = 504921600
16:42:42.274 -> 01/01/16 00:00:00
16:42:43.269 -> Unix time = 1451606400
16:42:43.269 -> Seconds since Jan 1 2000 = 504921600
16:42:43.269 -> 01/01/16 00:00:01
16:42:44.264 -> Unix time = 1451606401
16:42:44.264 -> Seconds since Jan 1 2000 = 504921601
16:42:44.264 -> 01/01/16 00:00:02
16:42:45.260 -> Unix time = 1451606402
16:42:45.260 -> Seconds since Jan 1 2000 = 504921602
16:42:45.260 -> 01/01/16 00:00:02
16:42:46.256 -> Unix time = 1451606403
16:42:46.256 -> Seconds since Jan 1 2000 = 504921603
16:42:46.256 -> 01/01/16 00:00:03
16:42:47.253 -> Unix time = 1451606404
16:42:47.253 -> Seconds since Jan 1 2000 = 504921604
16:42:47.253 -> 01/01/16 00:00:04
16:42:48.248 -> Unix time = 1451606405
16:42:48.248 -> Seconds since Jan 1 2000 = 504921605
16:42:48.248 -> 01/01/16 00:00:05
16:42:49.277 -> Unix time = 1451606406
16:42:49.277 -> Seconds since Jan 1 2000 = 504921606
16:42:49.277 -> 01/01/16 00:00:06
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - LSE is working - next reset
16:42:54.332 -> Select clock Source:
16:42:54.332 -> 1- LSI_CLOCK
16:42:54.332 -> 2- LSE_CLOCK
16:42:54.332 -> 3- HSE_CLOCK
16:42:54.332 ->
16:42:54.332 -> Enter number [1-3] 2
16:43:02.385 -> Test will use LSE_CLOCK
16:43:02.385 -> Testing asynchronous and synchronous prescaler setting
16:43:02.385 -> Async/Sync for default LSI clock: 0/0
16:43:06.403 -> Async/Sync for selected clock: 0/0
16:43:07.399 -> User Async/Sync reset use the computed one: 0/0
16:43:11.381 -> Testing date and time
16:43:11.381 -> 24H format, new year
16:43:12.742 -> 12/31/17 23:59:56
16:43:13.738 -> 12/31/17 23:59:56
16:43:14.733 -> 12/31/17 23:59:57
16:43:15.729 -> 12/31/17 23:59:58
16:43:16.725 -> 12/31/17 23:59:59
16:43:17.754 -> 01/01/18 00:00:00
16:43:18.749 -> 01/01/18 00:00:00
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - LSE is working...

@lucky62 can you provide me your mail ID.
Mine : arunshanagonda777@gmail.com

Hi all,

please @arun912-ux avoid to open several issue for the same thing. Thanks.
I will check that soon. Maybe there is a regression on F1, I need to test.

Hi all,

please @arun912-ux avoid to open several issue for the same thing. Thanks.
I will check that soon. Maybe there is a regression on F1, I need to test.

Sorry. It's my 1st time being on Github. I'll not do this again.
Thanks.

This situation is very difficult to reproduce on my environment.
There is an Errata Sheet published by ST for STM32F10xx8 STM32F10xxB
which applies to this device.

Workaround
It is recommended to mount an additional parallel feedback resistor 
(from 16 MΩ to 22 MΩ) on board to help the oscillation start-up in all cases 
(see Figure 1).

ES096_LSE start-up in harsh environments

Could the workaround help fixing this issued ?

another tentative with a sw approach could be to switch LSE clock OFF and ON until the flag LSE_RDY is set, in the (clock.c) enableClock(LSE_CLOCK) as follows:

int timeout = LSE_TIMEOUT_VALUE;
      if (__HAL_RCC_GET_FLAG(RCC_FLAG_LSERDY) == RESET) {

        __HAL_RCC_LSE_CONFIG(RCC_LSE_ON);
        /* loop switching LSE on again */
        while (__HAL_RCC_GET_FLAG(RCC_FLAG_LSERDY) !=1) {
          timeout--;
          if (timeout == 0) {
                  __HAL_RCC_LSE_CONFIG(RCC_LSE_OFF);
                  timeout = LSE_TIMEOUT_VALUE;
                  __HAL_RCC_LSE_CONFIG(RCC_LSE_ON);
          }
        }

This issue was not reproduced.
No feedback from OP about @FRASTM comments.
So I close it.