Bookbinder does not bind the SATP boresight encoder
mhasself opened this issue · comments
Matthew Hasselfield commented
Because this line checks for the wrong key.
The key "Corrected_Boresight" is correct.
Obviously the fix is trivial but this should be tested on the E2E system, and then I would like to inspect the output (cf #524).
Please consider this high priority, as we need the boresight position in the Books from day 1, which is nearly upon us.
Brian Koopman commented
The E2E system is still having some issues following our recent network migration. I'll look into those problems more now.
Brian Koopman commented
OK, I've solved the problem that I was running into. There are still some services offline following a reboot of that system, but I think everything else is working as expected.