With entities without a unique_id it is not possible to add these to a area. I have added unique_id's for all devices. So you can copy/paste it:

  - platform: mqtt
    name: "solarmanpv_station_generationPower"
    state_topic: "solarmanpv/station/generationPower"
    unique_id: "generatedPower"
    unit_of_measurement: "Wh"
    device_class: energy
    state_class: measurement

  - platform: mqtt
    name: "solarmanpv_inverter"
    unique_id: "solarmanpv_inverter"
    state_topic: "solarmanpv/inverter/deviceState"
    json_attributes_topic: "solarmanpv/inverter/attributes"
    
  - platform: mqtt
    name: "solarmanpv_logger"
    unique_id: "solarmanpv_logger"
    state_topic: "solarmanpv/logger/deviceState"
    json_attributes_topic: "solarmanpv/logger/attributes"

  - platform: template
    sensors:
      solarmanpv_inverter_device_state:
        unique_id: "inverter_device_state"
        value_template: >-
          {% set mapper =  {
              '1' : 'Online',
              '2' : 'Failure',
              '3' : 'Offline'} %}
          {% set state =  states.sensor.solarmanpv_inverter.state %}
          {{ mapper[state] if state in mapper else 'Unknown' }}
         
  - platform: template
    sensors:
      solarmanpv_logger_device_state:
        unique_id: "logger_device_state"
        value_template: >-
          {% set mapper =  {
              '1' : 'Online',
              '2' : 'Failure',
              '3' : 'Offline'} %}
          {% set state =  states.sensor.solarmanpv_logger.state %}
          {{ mapper[state] if state in mapper else 'Unknown' }}

template:
  - sensor:
      - name: "Solarman energy daily"
        unique_id: "solarman_energy_daily"
        unit_of_measurement: 'kWh'
        state: "{{ state_attr('sensor.solarmanpv_inverter', 'Daily_Production_(Active)') }}"
        device_class: energy
        state_class: measurement
        attributes:
          last_reset: '1970-01-01T00:00:00+00:00'

  - sensor:
    - name: solarmanpv_inverter_dc_voltage_pv1
      unique_id: "solarmanpv_inverter_dc_voltage_pv1"
      unit_of_measurement: 'V'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV1') }}"
      state_class: measurement

  - sensor:
    - name: solarmanpv_inverter_dc_current_pv1
      unique_id: "solarmanpv_inverter_dc_current_pv1"
      unit_of_measurement: 'A'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV1') }}"
      state_class: measurement

  - sensor:
    - name: solarmanpv_inverter_dc_voltage_testing
      unique_id: "solarmanpv_inverter_dc_current_testing"
      unit_of_measurement: 'V'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV1') }}"
      state_class: measurement
      unit_of_measurement: 'A'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV1') }}"
      state_class: measurement

  - sensor:
    - name: solarmanpv_inverter_dc_voltage_pv2
      unique_id: " solarmanpv_inverter_dc_voltage_pv2"
      unit_of_measurement: 'V'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV2') }}"
      state_class: measurement
  - sensor:
    - name: solarmanpv_inverter_dc_current_pv2
      unique_id: "solarmanpv_inverter_dc_current_pv2"
      unit_of_measurement: 'A'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV2') }}"
      state_class: measurement
      
  - sensor:
    - name: solarmanpv_inverter_dc_power_pv1
      unique_id: "solarmanpv_inverter_dc_power_pv1"
      unit_of_measurement: 'W'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV1') }}"
      state_class: measurement
      
  - sensor:
    - name: solarmanpv_inverter_dc_power_pv2
      unique_id: "solarmanpv_inverter_dc_power_pv2"
      unit_of_measurement: 'W'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV2') }}"
      state_class: measurement
      
  - sensor:
    - name: solarmanpv_inverter_total_production
      unique_id: "solarmanpv_inverter_total_production"
      unit_of_measurement: 'kWh'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'Cumulative_Production_(Active)') }}"
      state_class: total_increasing
      
  - sensor:
    - name: solarmanpv_inverter_daily_production
      unique_id: "solarmanpv_inverter_daily_production"
      unit_of_measurement: 'kWh'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'Daily_Production_(Active)') }}"
      state_class: total_increasing

  - sensor:
    - name: solarmanpv_inverter_ac_radiator_temp
      unique_id: "solarmanpv_inverter_ac_radiator_temp"
      unit_of_measurement: '°C'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'Temperature-_Inverter') }}"
      state_class: measurement
      
  - sensor:
    - name: solarmanpv_inverter_ac_voltage_1
      unique_id: "solarmanpv_inverter_ac_voltage_1"
      unit_of_measurement: 'V'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_R/U/A') }}"
      state_class: measurement
  - sensor:
    - name: solarmanpv_inverter_ac_current_1
      unique_id: "solarmanpv_inverter_ac_current_1"
      unit_of_measurement: 'A'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_R/U/A') }}"
      state_class: measurement
  - sensor:
    - name: solarmanpv_inverter_ac_voltage_2
      unique_id: "solarmanpv_inverter_ac_volgage_2"
      unit_of_measurement: 'V'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_S/V/B') }}"
      state_class: measurement
  - sensor:
    - name: solarmanpv_inverter_ac_current_2
      unique_id: "solarmanpv_inverter_ac_current_2"
      unit_of_measurement: 'A'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_S/V/B') }}"
      state_class: measurement
  - sensor:
    - name: solarmanpv_inverter_ac_voltage_3
      unique_id: "solarmanpv_inverter_ac_voltage_3"
      unit_of_measurement: 'V'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_T/W/C') }}"
      state_class: measurement

  - sensor:
    - name: solarmanpv_inverter_ac_current_3
      unique_id: "solarmanpv_inverter_ac_current_3"
      unit_of_measurement: 'A'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_T/W/C') }}"
      state_class: measurement

  - sensor:
    - name: solarmanpv_inverter_ac_output_frequency
      unique_id: "solarmanpv_inverter_ac_output_frequency"
      unit_of_measurement: 'Hz'
      state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Output_Frequency_R') }}"
      state_class: measurement

`