Entities with a UNIQUE_ID are needed to add a area
mhoogenbosch opened this issue · comments
Martijn Hoogenbosch commented
With entities without a unique_id it is not possible to add these to a area. I have added unique_id's for all devices. So you can copy/paste it:
- platform: mqtt
name: "solarmanpv_station_generationPower"
state_topic: "solarmanpv/station/generationPower"
unique_id: "generatedPower"
unit_of_measurement: "Wh"
device_class: energy
state_class: measurement
- platform: mqtt
name: "solarmanpv_inverter"
unique_id: "solarmanpv_inverter"
state_topic: "solarmanpv/inverter/deviceState"
json_attributes_topic: "solarmanpv/inverter/attributes"
- platform: mqtt
name: "solarmanpv_logger"
unique_id: "solarmanpv_logger"
state_topic: "solarmanpv/logger/deviceState"
json_attributes_topic: "solarmanpv/logger/attributes"
- platform: template
sensors:
solarmanpv_inverter_device_state:
unique_id: "inverter_device_state"
value_template: >-
{% set mapper = {
'1' : 'Online',
'2' : 'Failure',
'3' : 'Offline'} %}
{% set state = states.sensor.solarmanpv_inverter.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
- platform: template
sensors:
solarmanpv_logger_device_state:
unique_id: "logger_device_state"
value_template: >-
{% set mapper = {
'1' : 'Online',
'2' : 'Failure',
'3' : 'Offline'} %}
{% set state = states.sensor.solarmanpv_logger.state %}
{{ mapper[state] if state in mapper else 'Unknown' }}
template:
- sensor:
- name: "Solarman energy daily"
unique_id: "solarman_energy_daily"
unit_of_measurement: 'kWh'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'Daily_Production_(Active)') }}"
device_class: energy
state_class: measurement
attributes:
last_reset: '1970-01-01T00:00:00+00:00'
- sensor:
- name: solarmanpv_inverter_dc_voltage_pv1
unique_id: "solarmanpv_inverter_dc_voltage_pv1"
unit_of_measurement: 'V'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_dc_current_pv1
unique_id: "solarmanpv_inverter_dc_current_pv1"
unit_of_measurement: 'A'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_dc_voltage_testing
unique_id: "solarmanpv_inverter_dc_current_testing"
unit_of_measurement: 'V'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV1') }}"
state_class: measurement
unit_of_measurement: 'A'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_dc_voltage_pv2
unique_id: " solarmanpv_inverter_dc_voltage_pv2"
unit_of_measurement: 'V'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Voltage_PV2') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_dc_current_pv2
unique_id: "solarmanpv_inverter_dc_current_pv2"
unit_of_measurement: 'A'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Current_PV2') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_dc_power_pv1
unique_id: "solarmanpv_inverter_dc_power_pv1"
unit_of_measurement: 'W'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV1') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_dc_power_pv2
unique_id: "solarmanpv_inverter_dc_power_pv2"
unit_of_measurement: 'W'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'DC_Power_PV2') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_total_production
unique_id: "solarmanpv_inverter_total_production"
unit_of_measurement: 'kWh'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'Cumulative_Production_(Active)') }}"
state_class: total_increasing
- sensor:
- name: solarmanpv_inverter_daily_production
unique_id: "solarmanpv_inverter_daily_production"
unit_of_measurement: 'kWh'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'Daily_Production_(Active)') }}"
state_class: total_increasing
- sensor:
- name: solarmanpv_inverter_ac_radiator_temp
unique_id: "solarmanpv_inverter_ac_radiator_temp"
unit_of_measurement: '°C'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'Temperature-_Inverter') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_voltage_1
unique_id: "solarmanpv_inverter_ac_voltage_1"
unit_of_measurement: 'V'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_R/U/A') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_current_1
unique_id: "solarmanpv_inverter_ac_current_1"
unit_of_measurement: 'A'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_R/U/A') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_voltage_2
unique_id: "solarmanpv_inverter_ac_volgage_2"
unit_of_measurement: 'V'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_S/V/B') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_current_2
unique_id: "solarmanpv_inverter_ac_current_2"
unit_of_measurement: 'A'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_S/V/B') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_voltage_3
unique_id: "solarmanpv_inverter_ac_voltage_3"
unit_of_measurement: 'V'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Voltage_T/W/C') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_current_3
unique_id: "solarmanpv_inverter_ac_current_3"
unit_of_measurement: 'A'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Current_T/W/C') }}"
state_class: measurement
- sensor:
- name: solarmanpv_inverter_ac_output_frequency
unique_id: "solarmanpv_inverter_ac_output_frequency"
unit_of_measurement: 'Hz'
state: "{{ state_attr('sensor.solarmanpv_inverter', 'AC_Output_Frequency_R') }}"
state_class: measurement
`
Martijn Pepping commented
Thanks for the addition @mhoogenbosch! It's in the README now.