[Bug]: Incorrect labeling on ABSIS_ATX_PSU_BREAKOUT in system interconnect PDF
5k33tz opened this issue · comments
Discord Username
5k33tz
Bug Summary
Mismatch between interconnect diagram and silkscreen on PCB. J28, J29, and J30 Incorrectly labeled for ABSIS_ATX_PSU_BREAKOUT on interconnect diagram pdf.
The interconnect shows the following:
J28 - EXT_5V_IN (unused)
J29 - XDCR_AMP_PWR
J30 - EXT_12V_IN (unused)
Silkscreen for PCB in KiCad has the following:
J28 - EXT_12V_IN
J29 - EXT_5V_IN
J30 - BUTTKICKER IN
Correct labeling on interconnect PDF should read as:
J28 - EXT_12V_IN (unused)
J29 - EXT_5V_IN (unused)
J30 - XDCR_AMP_PWR
Expected Results
Correct labeling on interconnect PDF should read as:
J28 - EXT_12V_IN (unused)
J29 - EXT_5V_IN (unused)
J30 - XDCR_AMP_PWR
Actual Results
The interconnect shows the following:
J28 - EXT_5V_IN (unused)
J29 - XDCR_AMP_PWR
J30 - EXT_12V_IN (unused)
Screenshots/Images/Files
Applicable Part Numbers
OH-INTERCONNECT - OPENHORNET SYSTEM INTERCONNECT_-_v9.pdf
Release Version
1.0.0-beta.1
Category
Electrical (PCBs/Wiring/etc)
Applicable End Item(s)
Lower Instrument Panel (LIP)
Built to print?
- I built (or attempted to build) the part to the OpenHornet print without any deviations.
- I am not building this part to the OH print. (List deviations in detail in the Miscellaneous Info text area below.)
Miscellaneous Info
No response
Closed with 067946c