V4.1
GoogleCodeExporter opened this issue · comments
Google Code Exporter commented
Since Arduino V1.0, Serial.flush() is needed to flush out all the characters in
the transmit buffer. SimpleModbusSlave did not implement this and as a result
when half duplex communication is used with a MAX485/487 driver the full frame
was not transmitted.
This is now fixed in V4.1. Tested 100%
Original issue reported on code.google.com by bester.j...@gmail.com
on 2 May 2012 at 11:37
Google Code Exporter commented
Hey.
FIO does not work, any known incompatibility?
With Mega ONE and no problems
regards
Original comment by j.cueli....@gmail.com
on 12 Jun 2012 at 6:36
Attachments:
Google Code Exporter commented
The FIO only goes to 57600bps at the 8MHz specified. So anything above 57600bps
wont work.
Original comment by bester.j...@gmail.com
on 12 Jun 2012 at 11:20