write single coil to trigger imput on robot with ESP32. ModBus TCP protocol
kiksonix opened this issue · comments
I need help. I want to write single coil to trigger imput on robot. Coil adress is 1002. [01002]
I get E4 and E6 error.
Code is bellow:
#ifdef ESP8266
#include <ESP8266WiFi.h>
#else
#include <WiFi.h>
#endif
#include <ModbusIP_ESP.h>
const int REG = 1002; // Modbus Coils Offset
const int COUNT = 1; // Count of Coils
IPAddress remote(172, 29, 0, 179); // Address of Modbus Slave device
ModbusIP mb; // ModbusIP object
void setup() {
Serial.begin(115200);
WiFi.begin("");
while (WiFi.status() != WL_CONNECTED) {
delay(500);
Serial.print(".");
}
Serial.println("");
Serial.println("WiFi connected");
Serial.println("IP address: ");
Serial.println(WiFi.localIP());
mb.client();
}
bool cb(Modbus::ResultCode event, uint16_t transactionId, void* data) { // Modbus Transaction callback
if (event != Modbus::EX_SUCCESS) // If transaction got an error
Serial.printf("Modbus result: %02X\n", event); // Display Modbus error code
if (event == Modbus::EX_TIMEOUT) { // If Transaction timeout took place
mb.disconnect(remote); // Close connection to slave and
mb.dropTransactions(); // Cancel all waiting transactions
}
return true;
}
bool res[COUNT] = {true };
void loop() {
if (!mb.isConnected(remote)) { // Check if connection to Modbus Slave is established
mb.connect(remote); // Try to connect if no connection
Serial.print(".");
}
if (!mb.writeCoil(remote, REG, res, COUNT, cb)) // Try to Write array of COUNT of Coils to Modbus Slave
Serial.print("#");
mb.task(); // Modbus task
delay(50); // Pushing interval
}
E4 is Timeout error. E6 caused by reconnection after getting timeout (in cb
code).
Two possible reasons:
- Communication issues
- Read rate is too high for the server
Thank you. But What can I do now? Where can I slow down rate?
Simplest way is to wait response before sending next request. Also you may increase delay time.
void loop() {
if (!mb.isConnected(remote)) { // Check if connection to Modbus Slave is established
mb.connect(remote); // Try to connect if no connection
Serial.print(".");
}
if (uint16_t transaction_id = mb.writeCoil(remote, REG, res, COUNT, cb)) { // Try to Write array of COUNT of Coils to Modbus Slave
while (mb.isTransaction(transaction_id) {
mb.task(); // Modbus task
yield()
}
}
delay(50); // Pushing interval
}
Now I get only E4 error.
Can you please check the program if I put right data to specificate coils. I want to trigger imput on robot. Robot uses coils adreases 01001...02000 for triggers. I want to write coil 01002. Data type must be bool.
Thank you so much for help.
Program:`/*
Modbus-Arduino Example - Modbus IP Client (ESP8266/ESP32)
Write multiple coils to Slave device
(c)2019 Alexander Emelianov (a.m.emelianov@gmail.com)
https://github.com/emelianov/modbus-esp8266
*/
#ifdef ESP8266
#include <ESP8266WiFi.h>
#else
#include <WiFi.h>
#endif
#include <ModbusIP_ESP.h>
const int REG = 1002; // Modbus Coils Offset
const int COUNT = 1; // Count of Coils
IPAddress remote(172, 29, 0, 179); // Address of Modbus Slave device
ModbusIP mb; // ModbusIP object
void setup() {
Serial.begin(115200);
WiFi.begin("...", "...");
while (WiFi.status() != WL_CONNECTED) {
delay(500);
Serial.print(".");
}
Serial.println("");
Serial.println("WiFi connected");
Serial.println("IP address: ");
Serial.println(WiFi.localIP());
mb.client();
}
bool cb(Modbus::ResultCode event, uint16_t transactionId, void* data) { // Modbus Transaction callback
if (event != Modbus::EX_SUCCESS) // If transaction got an error
Serial.printf("Modbus result: %02X\n", event); // Display Modbus error code
if (event == Modbus::EX_TIMEOUT) { // If Transaction timeout took place
mb.disconnect(remote); // Close connection to slave and
mb.dropTransactions(); // Cancel all waiting transactions
}
return true;
}
bool res[COUNT] = {true };
void loop() {
if (!mb.isConnected(remote)) { // Check if connection to Modbus Slave is established
mb.connect(remote); // Try to connect if no connection
Serial.print(".");
}
if (uint16_t transaction_id = mb.writeCoil(remote, REG, res, COUNT, cb)) { // Try to Write array of COUNT of Coils to Modbus Slave
while (mb.isTransaction(transaction_id)) {
mb.task(); // Modbus task
yield();
}
}
delay(50); // Pushing interval
}`
There is no response from the server. Double check network connectivity between client and server. Also probably you need to specify unit_id in writeCoil (you need to refer the server docs).
Is there any chance that you can fix me the program please.
Can just suggest
if (uint16_t transaction_id = mb.writeCoil(remote, REG, res, COUNT, cb, 1)) { // where 1 is UnitID