AD9081 HD setting from updated UG
tfcollins opened this issue · comments
UG says HD = 1 for cases where M × S < L. This mode (8x1) !< 4
ref: https://www.analog.com/media/en/technical-documentation/user-guides/ad9081-ad9082-ug-1578.pdf (pg 110).
Seems to be the same rule for TX and RX. JIF mode tables set HD to 0 as well.
Hope I didn't miss something (:
can be closed now