On/Off issue with Fibaro Single Switch 2 FGS-213 ZW5

ab-ip opened this issue · comments

The status is not changed on On/Off action.
Module is visible and sends the events to the Hub but it stopped to react at status change action On/Off.
I tried to install Edge Driver from the GIT Repo but it is still the same result as the default driver. I suppose it is the same driver.
Here are the outputs of status command and logs of switch:off command from logcat:

$ smartthings devices:status e13a3cd6-cf80-41cc-af1b-c7f4e872d536
───────────────────────────────────────────────
 Capability   Attribute              Value     
 powerMeter   power                  0.9 W     
 button       button                           
 button       numberOfButtons                  
 button       supportedButtonValues            
 energyMeter  energy                 43.77 kWh 
 switch       switch                 "on"      
───────────────────────────────────────────────
$ smartthings devices:commands e13a3cd6-cf80-41cc-af1b-c7f4e872d536 switch:off
Command executed successfully
2023-05-03T21:43:59.846133003+00:00 TRACE Z-Wave Switch  Received event with handler capability
2023-05-03T21:43:59.864965003+00:00 TRACE Z-Wave Switch  Z-Wave command(ec1fd23d) queued for radio transmission: CC:Switch Multi-level, CID:0x01
2023-05-03T21:43:59.868148003+00:00 INFO Z-Wave Switch  <ZwaveDevice: e13a3cd6-cf80-41cc-af1b-c7f4e872d536 [0E] (Water Heater)> received command: {"args":{},"capability":"switch","command":"off","component":"main","positional_args":{}}
2023-05-03T21:43:59.869546336+00:00 TRACE Z-Wave Switch  Found CapabilityCommandDispatcher handler in zwave_switch
2023-05-03T21:43:59.870735003+00:00 TRACE Z-Wave Switch  SWITCH_MULTILEVEL supported.
2023-05-03T21:43:59.871870003+00:00 INFO Z-Wave Switch  <ZwaveDevice: e13a3cd6-cf80-41cc-af1b-c7f4e872d536 [0E] (Water Heater)> sending Z-Wave command: {args={duration="default", value="OFF_DISABLE"}, cmd_class="SWITCH_MULTILEVEL", cmd_id="SET", dst_channels={}, encap="AUTO", payload="\x00\xFF", src_channel=0, version=2}
2023-05-03T21:43:59.895642003+00:00 DEBUG Z-Wave Switch  Water Heater device thread event handled
2023-05-03T21:43:59.902864003+00:00 DEBUG Z-Wave Switch  Water Heater device thread event handled
2023-05-03T21:44:00.028741669+00:00 TRACE Z-Wave Switch  Z-Wave command(ec1fd23d) transmit status: TRANSMIT_COMPLETE_OK
2023-05-03T21:44:04.909451672+00:00 TRACE Z-Wave Switch  Z-Wave command(aa4364c7) queued for radio transmission: CC:Switch Multi-level, CID:0x02
2023-05-03T21:44:04.915591338+00:00 INFO Z-Wave Switch  <ZwaveDevice: e13a3cd6-cf80-41cc-af1b-c7f4e872d536 [0E] (Water Heater)> sending Z-Wave command: {args={}, cmd_class="SWITCH_MULTILEVEL", cmd_id="GET", dst_channels={}, encap="AUTO", payload="", src_channel=0, version=1}
2023-05-03T21:44:04.917119005+00:00 DEBUG Z-Wave Switch  Water Heater device thread event handled
2023-05-03T21:44:05.118872338+00:00 TRACE Z-Wave Switch  Z-Wave command(aa4364c7) transmit status: TRANSMIT_COMPLETE_OK

But the status stayed unchanged:

$ smartthings devices:status e13a3cd6-cf80-41cc-af1b-c7f4e872d536
───────────────────────────────────────────────
 Capability   Attribute              Value     
 powerMeter   power                  0.9 W     
 button       button                           
 button       numberOfButtons                  
 button       supportedButtonValues            
 energyMeter  energy                 43.77 kWh 
 switch       switch                 "on"      
───────────────────────────────────────────────