OpenEVSE / OpenEVSE_PLUS

OpenEVSE Hardware

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

Stuck relay

kallisti5 opened this issue · comments

Hey, the stuck relay detection works :-)

photo_2021-12-07_19-18-06

Had the 50A Struthers - Dunn contactor weld itself running at 32A. Anyone else have issues like that? The relay is only around a year old.

Looks like a few other people have seen this:
https://groups.google.com/g/openevse/c/4wFzy82jwYo

I lightly took a file to the contacts, then sanded with 400 grit, 2000 grit, and scrubbed the contactor with contact cleaner.
30A after 5 or 10 minutes and everything seems fine again without any excessive heat

photo_2021-12-07_20-03-57

We might want to add cleaning the contactor to yearly maintenance or something

I'm working on a contactor maintenance guide here:
https://openevse.dozuki.com/Guide/Contactor+maintenance/40

I need to get a few more pictures together before it's ready to publish

Published. I changed the language from Contactor to Relay. Technically these are more contactor-like vs relay-like, but the datasheet calls them relays... so I digress :-)

https://openevse.dozuki.com/Guide/Relay+Maintenance/40?lang=en