NREL / EnergyPlus

EnergyPlus™ is a whole building energy simulation program that engineers, architects, and researchers use to model both energy consumption and water use in buildings.

Home Page:https://energyplus.net

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

Source side outlet tempearture calculation uses loadside heat tranfer rate for temperature limit check

Nigusse opened this issue · comments

Issue overview

The source side outlet water temperature should have been calculated using the source side heat transfer rate not the load side heat transfer rate here. The calculated source side outlet temperature is used for checking if it exceeds the source side temperature limit and adjusting the PLR if needed. This is a defect.

Details

Some additional details for this issue (if relevant):

  • Platform (all operating system, develop)
  • Version of EnergyPlus (18f5c3f)

Checklist

Add to this list or remove from it as applicable. This is a simple templated set of guidelines.

  • Defect file added (list location of defect file here)
  • Ticket added to EnergyPlus Defect Complexity (Github Project)
  • Pull request created (the pull request will have additional tasks related to reviewing changes that fix this defect)