Deep-MI / fsqc

A set of quality control scripts for FreeSurfer- and FastSurfer-processed structural MRI data

Home Page:https://deep-mi.org

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

WM snr discrepancy between qatools and mri_segstats --qa-stats

WilliamFCB opened this issue · comments

Hi
I ran qa-tools and mri_segstats --qa-stats on a dataset and noticed that the norm wm snr reported by mri_segstats was higher than reported by qa_tools (respectively ~ 19.017 and 28.09)

Out of curiosity, is this because mri_segstats excludes the top and bottom 2% before calculating the WM stats?

thanks
William

Hi, and apologies for the very late reply. To be honest, I can only speculate about these differences. It is possible that the robust calculation in mri_segstats contributes to this difference. On the other hand, I don't know how the computation in mri_segstats is done exactly - and since ours is a free reimplementation, I would not expect perfect agreement a priori. One strategy for further investigation might be to look at the correlation of the metrics from the two packages in a larger sample.

Best regards, Kersten