ClockSelect / myevic

This is myevic Custom Firmware.

Geek Repo:Geek Repo

Github PK Tool:Github PK Tool

Wismec firmware update program not recognizing my Rx2/3 after using custom firmware

Angelshover opened this issue · comments

I added the myvic custom firmware a few weeks ago to my rx2/3. Its has world pretty good since. However I recently have been having a problem where the device won't let me go passed 72.3watts in power mode. I don't know if I changed a setting or something so I figured I'd just restore it to stock firmware and than redo it.

Problem is my computer nor the official Wismec firmware updating program will recognize my mod. It charges but still say "none device" and doesn't let me update.

After searching around here I found someone say changing this setting expert->USB->HID* so I tried all of those options and none worked.

Anyone ever have this issue or have a possible solution. Thanks in advance.

@SEEKNDESTROY you could try to use Safe Mode to flash your device.
Remove batteries.
Press Plus button while connecting the device.
Flash it. :)

Even if your device is theorically capaple of outputting 200W or so, it will not do so under any conditions. Depending on the resistance of the coil, the power will be limited by the 9 volts or 50 Amps cap, and the available power will be limited accordingly.
Even if the stock firmware let you configure anything up to 200W, it will stop feeding up the coil when it reaches 9V or 50A, and it may be those 72W. It just doesn't tell you.

For the firmware update issue, @Dil3mm4 gave you the answer.